<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-18 03-05-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 56 dBuV YLEX
Pilot RDS Phase Difference
7.6 kHz 2.4 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 64 kHz 19018 0,8886
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 3,49 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 3:05, 18.06.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 64 kHz MIN: 11 kHz % above 76 kHz: 0,8886 Acquired: 2025/06/18 3.04.14 Total samples: 19018 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,4 dBr MIN: 0,8 dBr AVE: 3,49 dBr % above 12,2 dBr: 0,0 Last value: 2,4 dBr (2025/06/18 3.04.14) 02.50 02.52 02.54 02.56 02.58 03.00 03.02 03.04 0 2 4 6 Pm [dBr]